Principle: | Corioliss | |
Material: | Stainless steel 304,316L | |
Display: | English LCD display | |
Output: | Pulse, 4--20mA output | |
Accuracy: | +_0.2 +_0.5 | |
Communic: | RS485,RS232,HART | |
Medium: | Liquid,mixture | |
Power: | 24VDC ,220VAC | |
Diameter: | DN15-DN150 | |
Max temp: | -40--200degC | |
Converter: | Integrated, separated | |
Warranty: | 12months | |
Brand: | XINSIER | |
Inquiry |
DESCRIPTION :
Mass flowmeter is designed according to the Coriolis Principle.under the alternating current the magnet and coil installed on
the measuring tube will make two parallel measuring tubes vibrate according to some fixed frequency. Once there is flow
passing through the pipes, Coriolis force will give rise to deflection (phase shift) on the vibration of two pipes and the
deflection of vibration is directly proportional to the mass flow of fluid. Pick up them and the mass flowrate could be calculated.
The vibration frequency of measuring tube is determined by the total mass of measuring tube and inner fluid. When then fluid
density changes, the vibration frequency of measuring tube will be also changing, as a result, the fluid density can be calculated.
The temperature transducer installed in the pipe line can pick up the fluid temperature on time under the coordination of
measuring circuit.
SPECIFICATIONS :
Mass Flowmeter has several series, the main difference is that design innovation on flow sensor measurement tube ;
Improve the accuracy , reliability, performance and sensitivity of instrument; Increase the measuring deflection, improve the
stress distribution, reduce fatigue damage; Strengthen the vibration resistance interference ability, etc.
FEATURES :
Quality flow measurement accuracy: 0.1% (0.1% stability)
Density measurement accuracy: 0.003g/cm3
Density measurement scope: 0 ~ 3g/cm3
Temperature measurement accuracy: 1 ℃ Temperature measuring scope: -60℃ ~ +200℃
Current output: 4 ~ 20mA
Frequency output: 0 ~ 10 kHz
Batch Control relay contact capacity: 24 V/0.1A
Medium Temperature: -60℃ ~+200℃ The ambient temperature: -30℃ ~ +60℃
Environment Humidity: ≤ RH90% non-condensing
Atmospheric pressure: 86 ~ 106KPa
This type of transmitter power requirements: power supply voltage AC (220 ± 10%) V, (50 ± 5%) HZ;
Compound transmitter power requirements: power supply voltage DC 24.4V
Complete machine power: <15 W
Explosion-proof composite signs: ExdⅡBT4